Product category:
Level and tank contents instrumentation
News Release from: ABB Automation Tech (Instrumentation + Automation) | Subject: 2600T
Edited by the Processingtalk Editorial
Team on 11 March 2005
Pressure transmitters for accurate
interface level
The merits of pressure transmitters for accurate interface level measurement are discussed, and a recent application of the ABB 2600T described for recovering hydrocarbons from tank washings
This article presents the merits of pressure transmitters for accurate interface level measurement Many processes use water as a means of transporting product from one point to another
This article was originally published on Processingtalk on 7 Oct 2005 at 8.00am (UK)
Related stories
Robust pressure performance in harsh environments
ABB has expanded its 2600T pressure transmitter range with the addition of a new device suitable for use in harsh process environments, manufactured from stainless steel all round
Pressure tx meets nuclear plant safety demands
British Energy has opted to use ABB programmable pressure transmitters for a safety-related application at its Torness nuclear power station, after meeting strict internal assessment criteria
For example, in oil production, water or steam is often used to lift oil out of a well.
In chemical production, water is sometimes a by-product or a tool used to clean a vessel.
In these situations, the water and hydrocarbons will mix together.
Further reading
IEC 61511 impact on safety instrumentation
The IEC 61508 compliant SIL approved 2600T pressure transmitter from ABB is helping to save on life cycle costs in a real-life application, according to a recent paper
Instruments from ABB at MTEC
ABB will present the latest technology from its comprehensive range of instrumentation products and systems at MTEC 2004 (Birmingham NEC, 11th and 12th February 2004)
New fully comprehensive pressure transmitter range
The ABB FieldIT 2600T pressure transmitter series offers the most complete ranges of pressure measurement equipment currently available, including remote seals, communications and SIL safety models
At some point, it will be necessary to remove the hydrocarbon from the water.
If allowed to settle undisturbed in a tank, the mixture will separate into its two components, with the heavier, denser material sinking to the bottom and the lighter, less dense material rising to the top.
This principle is exactly the same as the way in which oil and vinegar separates in an Italian salad dressing.
One example of this in a real application is a separation tank.
A control valve regulates the ingress of a liquid mixture of water and hydrocarbon into the vessel.
Eventually, the lighter material in the mixture finds it way up to the separation stack, where a water/hydrocarbon liquid interface forms - effectively a dividing line between the two liquids.
The position of this liquid interface is critical - too little or too much either way will end up with either water being drawn out with the hydrocarbon, or hydrocarbon remaining in the tank.
In either situation, the end result is reduced product quality and process efficiency, adding to the product cost.
When the mixture gets to the critical interface point, a pump will pull out the hydrocarbon from the stack while a continuous amount of new mixture is pumped into the tank.
The hydrocarbon is then sent on for processing, free of water.
For this process to operate at optimum efficiency, it is vital that the interface level is measured and controlled properly.
Typical methods used to measure interface level.
A range of different technologies exists for interface level measurement applications.
Many of these technologies can encounter problems when either the interface level becomes too small or the process involves sticky solids.
Substances that can coat or leave residue can also present a problem when using these devices.
Here, we will look at the advantages and disadvantages associated with the three main methods most commonly employed for interface level measurement, namely - displacers, capacitance probes and differential pressure transmitters.
Displacer type transmitters.
This method relies on the principle of buoyancy and consists of a large chamber flanged to the separation stack.
A float or element of a known specific gravity will float at the point of interface.
A series of moving part linkages attached to the float indicate the float's position to a transmitter, informing it of where the interface is.
Although relatively straightforward, this technique has a number of key disadvantages.
Firstly, petrochemical and chemical applications are often characterised by aggressive conditions, demanding the use of exotic materials, which can add substantially to the cost of the transmitter system.
The mechanical linkages can also stick, fouling the measurement and requiring frequent maintenance.
The overall accuracy of these devices is also often questionable - in some cases, customers have reported accuracies of just 10% at best.
Capacitance probes.
Capacitance probes comprise a long metallic probe, which normally enters the top of the separator vessel and extends to its lowest point.
Liquid level and interface are detected by measuring the capacitance value between the wall of the vessel holding the liquid and the probe itself.
Again, the aggressive nature of most chemical and petrochemical applications will require the use of exotic materials, adding to the cost of the installation.
Another complication associated with this technology is the measurement of sticky substances, which can coat the metal, resulting in measurement uncertainties and poor readings.
Other factors such as foam on the liquid surface or vibration of the tank can also conspire to reduce measurement certainty or even render the probe inoperable.
Remote seal differential pressure transmitters.
This technique offers probably the best solution for the measurement of liquid interface levels.
With this technique, when the distance between the taps on the separation stack is filled only with the lighter liquid, the differential pressure is minimum value or the lowest range value (LRV) of the transmitter.
When it is filled with the heavier liquid, the differential pressure is at its maximum value, or the upper range value (URV) of the transmitter.
Although this technique overcomes many of the problems associated with the previously described methods, particularly with respect to corrosion, it does have one main drawback.
The small difference in both the specific gravity of the two liquids and the distance between the taps on the separation stack results in a very small differential pressure span.
In many cases, the size of this span is often lower than the recommended minimum span for most remote seal transmitters.
One way of overcoming this problem is to use remote seals and transmitters which are sensitive enough to detect very low span changes.
An example is the ABB remote-seal based 2600T interface level transmitter, which has been specifically designed for use at very low differential pressures.
These transmitters use a remote seal with a highly sensitive diaphragm available with a range of fill fluids for a variety of applications.
Protection against leakage of the fill fluid is ensured by an all-welded construction, which offers a significantly extended service life than seals utilising a conventional gasket or thread construction, particularly in vacuum applications.
Application example.
A chemical plant wanted an interface level transmitter for use in a chemically aggressive hydrocarbon reprocessing application.
In this application, a mixture of process hydrocarbons cleaned from the plant's tanks and reactors, and water used for cleaning the reactors, was piped into a holding tank where it was allowed to settle.
The customer wanted to be able to pump the hydrocarbon back into the process for reclamation without also pumping any of the water.
In designing a solution, several obstacles had to be overcome.
Firstly, the application involved a very low differential pressure span impossible for most remote seal transmitters to measure.
A second challenge was the location of the application, which was subject to considerable swings in ambient temperature.
Such inconsistent conditions can often pose a potential problem when measuring very small pressure differentials.
To solve this problem, the entire transmitter, with remote seals connected, would have to be temperature characterised together in an environmental chamber.
A microprocessor-based ABB 2600T draft range differential pressure transmitter was installed because of its small upper range limit, suitable for the close requirements of the application.
The temperature characterisation data from the environmental chamber was stored in the transmitter memory.
The transmitter on-board temperature sensors monitor the ambient temperature.
Accurate pressure measurement is ensured by the transmitter microprocessor, which compares the data from the environmental chamber with the ambient temperature conditions and adjusts the transmitter output accordingly.
A major concern at the outset was the risk of any pressure imbalance inside the capillary system due to changes in ambient temperature, which would cause the fill fluid to expand or contract.
The effect of this potential change was calculated under laboratory conditions, with the uncertainty of the system being predicted to be less than 0.5% of span.
Since this new interface level transmitter was installed, the interface level control has greatly improved.
The customer has also reported that downtime has been eliminated, saving over GBP30,000 per year on the cost of maintenance alone.
Before this, monthly maintenance was required to clean the previously installed buoyancy transmitter system to prevent shutdowns.
Despite this, the instruments would frequently foul up anyway, resulting in the process being shut down.
Summary.
Selecting the right solution for an interface level measurement application requires consideration of many factors, including accuracy, aggressiveness of the application media and the level of maintenance deemed acceptable for the application.
Opting for a remote seal differential transmitter system provides an ideal solution for aggressive applications and can help to eliminate maintenance whilst delivering greatly enhanced measurement accuracy.
• ABB Automation Tech (Instrumentation + Automation): contact details and other news
• Email this article to a colleague
• Register for the free Processingtalk email newsletter
• Processingtalk Home Page