Outstanding multifunctional TOC analysis
The Multi N/C series of catalytic combustion analysers from Analytik Jena UK offer extraordinary versatility for TOC (Total Organic Carbon) and TNb (Total Bound Nitrogen) measurement
The novel design provides a TOC measuring range from 2ppb up to 30,000ppm without dilution and a fully integrated double furnace for the analysis of solids or liquids The exceptional measurement range is achieved using a multi-channel detector, which features 3 detectors to cover the entire measurement range, and a reference detector
This article was originally published on Processingtalk on 19 Feb 2008 at 8.00am (UK)
Related stories
Versatile TOC analyser from Analytik Jena
The Multi N/C series of catalytic combustion analysers have been designed for the fully automatic determination of bound carbon (TIC/TOC, TC, NPOC, POC) and/or total nitrogen (TNb)
Atomic absorption spectrophotometer Roadshow
Analytik Jena UK will be holding a UK-based roadshow during July 2008 featuring the contrAA series of High Resolution Continuum Source (HR-CS) atomic absorption spectrophotometers
The system is equipped with automatic detector selection, auto drift compensation and auto- zeroing.
Automatic detector selection means that samples can be analysed without dilution.
An easy to use and low maintenance Self Check System is used to control all system functions.
High accuracy of results is ensured using patented VITA technology, which automatically determines the retention time of the sample in the analyser.
This is achieved by real time measurement of the gas flow to allow the detector signal to be automatically corrected for variations in the flow.
VITA technology not only leads to good accuracy and sensitivity but also excellent repeatability.
VITA improves repeatability from typically 5-10% in the 0.5 - 1.0mg/l range and 3-5% in the 1000 to 5000mg/l range to 1-2% across the measuring ranges.
In addition, VITA significantly reduces the intervals between calibrations to around 6 months.
Multi N/C series instruments can be calibrated across the entire detection range using a single standard sample, eliminating the need for a large number of standard reference materials.
Additional versatility comes from the double furnace configuration which can be oriented vertically for liquid samples and horizontally for solid samples.
It is simple to switch between the two configurations.