Reagent-free residual chlorine measurement
Analytical Technology introduces a new free of charge application note entitled "Reagent free residual chlorine measurement, in process with variable and/or high pH"
Analytical Technology (ATi) introduces a new free of charge application note entitled "Reagent free Residual Chlorine Measurement, in process with variable and/or high pH".
The new application note discusses how the ATi Q45H62 monitoring system measures free chlorine residuals without the need for chemical buffering traditionally associated with such measurements.
Acetate and phosphate buffers are expensive and environmentally unfriendly, causing all major water companies to look for alternatives to traditional technology.
The ATi pH corrected monitor uses a membrane-covered polarographic sensor that does not require the addition of costly chemical reagents.
The new application note is of particular interest to water and wastewater companies, plus process, petrochemical, pharmaceutical, metals and food and beverage industries where water is used.
Traditional amperometric cells and polarographic probes only respond to hypochlorous acid (HOCI).
HOCI dissociates into hypochlorite (OCI-) in a pH dependent manner, leading to the need for chemical buffering in the majority of applications.
The typical pH of water measured on a water treatment works may range from 7 to 9.2, chemical buffering reduces the pH to between 5 and 6 and ensures that all the residual chlorine is present as HOCI.
Some manufacturers have proposed a combined HOCI and pH monitor could help eliminate the need for buffer.
However, there are a number of problems with such a monitor, including different response times, errors in pH measurements, low signals and the lack of standard response curves.
The ATi Q45H62 pH corrected chlorine monitor overcomes the problems of traditional amperometric monitors.
For example, the ATi sensor has a response time around 10 times higher than that of conventional sensors at high pH values (pH >8.3).
This means that the monitor can be used reagent free over all the pH values found in the UK drinking water industry.
In variable pH applications the Q45H62 utilises an optional pH compensation feature to eliminate free chlorine error caused by process pH drift.
If the correct sensor is used there is an extended response to chlorine at high pH levels, allowing pH correction to be employed over a much wider range.
In addition, the ATi sensor is resistant to many of the common contaminants found in water treatments, such as iron, manganese and poly phosphate.
The ATi pH corrected membrane monitors are proving as stable and accurate as traditionally buffered monitors, thus offering the water industry a new way forward.
As a result of a number of industry evaluations these monitors are fast becoming the preferred instrument of choice.
The findings on the accuracy of the ATi monitor are detailed in a new, free of charge process application note available from ATi.
For more information about the ATi pH corrected chlorine monitor, other ATi products or for a copy of the process application note, please use the 'request a brochure' service.
Not what you're looking for? Search the site.
Tel +44 145 783 2800
-
Analytical launches Autotest D12 gas monitor
Analytical Technology has released its D12 two-wire, loop-powered, toxic/combustible gas detector, a sensor that can provide accurate readings of over 30 gas concentrations. -
Water Quality Panel identifies water contaminants
Electrochemical sensor manufacturer Analytical Technology (ATi) has announced the availability of its Q45WQ Water Quality Panel. -
Analytical describes dissolved ozone monitoring
Analytical Technology has announced the availability of a technical note entitled 'Calibration of Dissolved Ozone Monitors on Ultra-Pure Water Loops'. -
Portable monitor for chlorine in water measurement
Specialist electrochemical sensor manufacturer Analytical Technology announces the availability of the new portable Q45H/62 Residual Chlorine Monitor, for fast and effective on-line measurement -
Dissolved ammonia monitor for wastewater control
Specialist electrochemical sensor manufacturer Analytical Technology announces that the new Q45N Dissolved Ammonia Monitor achieves continuous, on-line monitoring of wastewater
Categories
- Plant Instrumentation (5,478)
- Process Control and Management (2,525)
- Communications and HMI (2,535)
- Process Plant and Equipment (6,164)
- Processing Industry Events and Services (3,198)
- News from specific industry sectors (2,263)
- ENVIRO-Talk - Environment + Pollution (550)
- FLOWtalk - Flow Measurement (753)
- WATER-Talk - Water Industry News (1,211)