New integrating, recording, chlorine transmitter
Analytical Technology has introduced its B20 Recording Chlorine Transmitter for residual chlorine monitoring, where both measurement, and circular chart recordings are required
The system combines both a free or chloramine analyser inside a circular chart recorder to provide either 24 hour or seven day recording of chlorine residuals.
The transmitter can be used in a wide range of applications, including the treatment of potable water and the treatment of process water in the food and pharmaceutical industries.
Chloramine treatment is used in many UK water networks as they are a longer-lasting, although less effective, form of disinfectant than chlorine.
The level of residual chlorine in water is an indication of the effectiveness of the disinfection process, and by maintaining a small level of residual chlorine in the water it is possible to ensure a clean supply.
Providing permanent chlorine residual records normally means purchasing a residual chlorine monitor and connecting the output of the monitor to a separate recorder.
The ATi B20 provides an integrated solution to this problem, combining both the analyser and recorder functions in a single package.
This results in simpler installations, easier operation and lower cost.
In addition the system uses the ATi direct measuring membrane sensor for reliable measurement with minimal maintenance.
The sensor is a direct measuring polarographic membraned sensor that eliminates the need for chemical buffers and other reagents.
Sensors are available for free chlorine measurements or for combined chlorine monitoring where chloramine treatment is in use.
Chlorine sensors require a constant sample flow past the membrane to provide stable and accurate readings.
B20 systems are supplied with a constant-head flowcell assembly that automatically maintains the desired flow.
For more information about the ATi Recording Chlorine Transmitter or other ATi products please use the Processingtalk Reader Response service, or phone the sales office.
Not what you're looking for? Search the site.
Tel +44 145 783 2800
-
Analytical launches Autotest D12 gas monitor
Analytical Technology has released its D12 two-wire, loop-powered, toxic/combustible gas detector, a sensor that can provide accurate readings of over 30 gas concentrations. -
Water Quality Panel identifies water contaminants
Electrochemical sensor manufacturer Analytical Technology (ATi) has announced the availability of its Q45WQ Water Quality Panel. -
Analytical describes dissolved ozone monitoring
Analytical Technology has announced the availability of a technical note entitled 'Calibration of Dissolved Ozone Monitors on Ultra-Pure Water Loops'. -
Portable monitor for chlorine in water measurement
Specialist electrochemical sensor manufacturer Analytical Technology announces the availability of the new portable Q45H/62 Residual Chlorine Monitor, for fast and effective on-line measurement -
Dissolved ammonia monitor for wastewater control
Specialist electrochemical sensor manufacturer Analytical Technology announces that the new Q45N Dissolved Ammonia Monitor achieves continuous, on-line monitoring of wastewater
Categories
- Plant Instrumentation (5,478)
- Process Control and Management (2,525)
- Communications and HMI (2,535)
- Process Plant and Equipment (6,164)
- Processing Industry Events and Services (3,198)
- News from specific industry sectors (2,263)
- ENVIRO-Talk - Environment + Pollution (550)
- FLOWtalk - Flow Measurement (753)
- WATER-Talk - Water Industry News (1,211)