Product category: Liquid Analysis: Turbidity, Particles
News Release from: Analytical Technology | Subject: A15/76
Edited by the Processingtalk Editorial Team on 12 February 2008

Reliable low-range turbidity measurement

The Analytical Technology A15/76 Turbidity Monitor is capable of achieving reliable low-range measurements of turbidity levels in both drinking water and industrial water treatment applications

Turbidity is measured in nearly all water systems and is a general indicator of the optical clarity of water The A15/76 Turbidity Monitor from ATi is capable of accurately measuring turbidity in clean or waste water

In clean water applications, the unique sensor flowcell eliminates sample degassing for precise and reliable results.

In dirty water applications, the ATi Auto-Clean system allows reliable accurate measurement without the need for constant cleaning.

According to the World Health Organisation (WHO), the level of turbidity in drinking water should not exceed 5NTU (Nephelometric Turbidity Units), and ideally should be less than 1NTU.

The A15/76 Turbidity Monitor from ATi is capable of achieving precise turbidity measurements as low as 0.001NTU and as high as 4000NTU within a single system, and eliminates the need for separate high and low range instruments.

Turbidity levels are traditionally difficult and time-consuming to measure; however the ATi A15/76 sensor is designed to operate under pressure to eliminate air bubbles which are a common problem in many turbidimeters, often causing air bubble errors.

The turbidity sensor used in the A15/76 monitor is a planar sensor with the light source and photo detector mounted on a flat face.

The signal generated by the detector is amplified inside the sensor for transmission to the display unit.

Periodic pulsing of the light source allows the sensor zero to be adjusted automatically for improved stability in low-range applications.

Dual beam technology compensates for any sensor fouling or long term degradation of the light source or detector.

When used in conjunction with the ATi air blast Auto-Clean system the monitor can also be in industrial water treatment and can aid compliance with effluent control as part of the Integrated Pollution Prevention and Control (IPPC) guidelines.

Under these regulations, manufacturers must demonstrate that they are implementing the 'Best Available Technology' (BAT) to control water emissions and provide a high level of protection to the environment as a whole.

The essence of BAT is that the selection of techniques to protect the environment should achieve an appropriate balance between the environmental benefits and the costs incurred by operators.

The ATi D15/76 Turbidity Monitor also provides manufacturers with a cost-effective BAT.

The "air-blast" sensor cleaning system automatically cleans the sensor as often as necessary to maintain reliable measurements. Request a free brochure from Analytical Technology ...