BSI, British Standards, has just published a revised guide to the specific requirements for the construction and testing of electrical apparatus with pressurized enclosures, of type of protection "p"
Equipment used in hazardous areas possess features specially designed to render them suitable for operations in such atmospheres It is essential for reasons of safety in those areas that, throughout the life of such installations, the integrity of those special features is preserved
This article was originally published on Processingtalk on 10 Jul 2006 at 8.00am (UK)
Related stories
Manage cleanrooms and controlled environments
A new BSI standard supports the management and control of cleanrooms and other associated controlled environments
Improve the productivity of your web-pages
To avoid user-frustration and Web application failure caused by poorly managed webpages the BSI has published a new software engineering standard for those who design, implement and manage webpages
The newly released BS EN 60079-2:2007 specifies requirements for pressurized enclosures containing a limited release of a flammable substance.
The standard gives requirements for the design, construction, testing and marking of electrical apparatus for use in potentially explosive atmospheres in which: a) a protective gas maintained at a pressure above that of the external atmosphere is used to guard against the formation of an explosive gas atmosphere within enclosures which do not contain an internal source of release of flammable gas or vapour; and, where necessary b) a protective gas is provided in sufficient quantity to ensure that the resultant mixture concentration around the electrical parts is maintained at a value outside the explosive limit appropriate to the particular conditions of use.
The protective gas is supplied to an enclosure containing one or more internal sources of release in order to guard against the formation of an explosive gas atmosphere.
BS EN 60079-2 includes requirements for the apparatus and its associated equipment including the inlet and exhaust ducts, and also for the auxiliary control apparatus necessary to ensure that pressurisation and/or dilution is established and maintained.
The price is GBP142, with a Member price of GBP71: ISBN 978 0 580 54512 2.