Gas detection system gives stand-alone
control
The new Det-Tronics DMC Series gas and flame controller provides continuous indication and alarm control of up to 36 programmable channels of toxic and/or combustible gas detection
The new Det-Tronics DMC Series gas and flame controller provides continuous indication and alarm control of up to 36 programmable channels of toxic and/or combustible gas detection, with full stand-alone functionality in a single weatherproof and corrosion resistant wall-mounted enclosure An integrated PLC offers custom logic programming and communications options including Modbus and Ethernet, with password-protected front panel field configuration of sensor types, ranges and alarm output level using the onboard keypad and display
This article was originally published on Processingtalk on 13 Dec 2005 at 8.00am (UK)
Related stories
Fire/gas system and IR detectors in chemical plant
Det-Tronics combined fire/gas detection and extinguishing agent release systems with infrared flame detectors protect production and storage facilities at a Cognis plant producing chemical products
Triple IR Flame detectors are a better choice
BMW Munich specified Det-Tronics X3001 triple infra-red flame detectors for spray painting booth fire protection because of their complete false alarm resistance
Easy to install and commission, the system delivers exceptional cost-effective protection for a wide range of industrial applications and is available with an internal 24V dc power supply.
It accepts 4-20mA inputs from a wide variety of detector types and measurement ranges and can also monitor contact input devices such as optical flame detectors or smoke detectors.
Four versions accommodate 4, 12, 24 or 36 channels, each with selectable high and low level alarm setpoint levels, that are automatically matched to the selected detector type and range.
An optional flame detector channel designator is selectable.
As well as a faceplate display, all alarm or fault events are time and date-stamped and stored in non-volatile memory to aid trouble-shooting.
Standard common alarm logic is provided for fault conditions and horn and strobe outputs as well as high/low setpoints.
A stacked input/output module design supports up to four I/O modules in a single unit.
The rugged NEMA 4X/IP66 fibreglass enclosure suits non-hazardous indoor or outdoor installation.
It has a transparent cover that opens for easy access and a DIN rail-mounted terminal strip to accommodate all power, detector input and output field wiring connections.