Flow monitor for large diameter pipes
New E-T-A flow monitor and extended monitoring head provide accurate measurements in large diameter pipes or through thick-walled insulation, for ventilation, cooling and lubrication circuits
E-T-A Circuit Breakers has extended its range of flow monitoring products by introducing a new flow monitor and extended, push-fit, monitoring head which together provide accurate flow measurements in larger pipe sizes as well as in pipes with thick walled insulation.
With a wide range of operating temperatures, they are ideally suited for monitoring cooling and lubrication circuits, as well as ventilation and cooling equipment.
Optimal positioning of flow sensors in a pipeline, where the flow is laminar, is essential for reliable and accurate flow monitoring.
It is also important to insert the monitoring head far enough into the flow-stream of the medium.
The new E-T-A FS20 Flow Monitor and 300mm long MKV Monitoring Head are designed to overcome these problems by providing compact single-point flow monitoring in applications with pipe sizes of DN65 or more, as well as in cooling equipment with thick-walled insulation.
The MKV is installed using a compression gland: the tip of the monitoring head needs to be inserted to only one-eighth of the internal diameter of the pipe/duct work, so that extremely large diameters can be accommodated.
To save space, the electronic control unit of the FS20 is accommodated within the stainless steel monitoring head, and with no moving parts they are practically wear and maintenance free.
The operating temperature range is from -40C to +100C.
The FS20 switch point can be adjusted for MIN or MAX flow rates between 0.5m/s and 50m/s for air/gases, and between 0.01m/s and 4.5m/s for water or oil.
Simple, step-less switch point adjustment is by means of a potentiometer.
Electronic signalling is short-circuit proof via a power MOSFET, with electrical connection for the 24V DC supply voltage and signal cable via a 3-pole M12 plug connector to IEC947.
Interruption of the supply voltage lights an LED on the monitor and creates a flow failure signal.
Not what you're looking for? Search the site.
Tel +44 1296 420336
-
Plant and process control system circuit breaker
E-T-A Circuit Breakers has introduced a new, compact, rail-mountable, thermal-magnetic circuit breaker for overcurrent protection of loads and their supply cables in plant and process control systems -
Overcurrent protection in automation applications
E-T-A Circuit Breakers has introduced a new DIN-rail mounted version of its compact ESX10 electronic overcurrent protection product for automation applications -
PCB reduces wiring times of 19inch racks
E-T-A Circuit Breakers has introduced a newly designed printed circuit board (PCB) for the E-T-A 19BGT 19inch rack, to reduce wiring times -
A new, cost-effective water low-flow alarm
The E-T-A FS30 incorporates a robust, membrane-type sensor which will monitor flow rates from 0.25m/s to 3m/s, providing an alarm when the flow rate falls below an adjustable, pre-set minimum value -
Cost optimised versions of E-T-A Smart Power Relay
E-T-A Circuit Breakers has introduced a cost-optimised version of its cubic-version Smart Power Relay, offering circuit breaker protection from a remotely controllable electronic switching relay