London's water runs better on pneumatics
A 1600mm butterfly valve at the Thames Water Ashford Common water treatment plant is now controlled by a pneumatic actuator system designed and produced by Festo
Thames Water is justifiably proud of its Ashford Common water treatment plant It processes about 690 million litres a day and satisfies a quarter of London's entire potable water needs
This article was originally published on Processingtalk on 3 Feb 2004 at 8.00am (UK)
Related stories
Festo launches new products and services
Europe's leading pneumatics and automation company, Festo, will be actively participating in this year's PPMA show at the TOTAL Processing and Packaging Exhibition
IP69K-rated washdown valve terminals for food use
An innovative volumetric depositor of garlic butter into dough balls uses Festo IP69K-rated washdown valve terminals to maximise performance and machine uptime! And it injects 14,000 balls an hour....
Ashford Common is one of the larger treatment plants clustered on the Thames above Teddington Weir - others include Hampton, Walton and Kempton.
The Ashford Common plant is supplied by five fixed-speed pumps, and employs a 1600mm butterfly valve as a gravity bypass and to control flows onto the works.
The valve is located halfway down a 30metre shaft.
Further reading
Service engineer communication skills training
Following a successful debut, Festo Didactic announces further dates for its new two-day seminar, 'Communication skills for service engineers' for improving customer communications
Batch-weighing innovation via automation design
Fieldbus-controlled weighing/handling system with intelligent carts
fully automates production of minor ingredient recipes for plastic, rubber and
chemical processing
Pneumatics-friendly Ethernet PLC for automation
The new Festo Ethernet-equipped PLC is believed to be the first truly integrated solution for pneumatic valve terminals: protected to IP67, it can be mounted directly in harsh washdown environments
Towards the end of last year, Thames Water commissioned a replacement for this main gravity valve, because although the existing electrically-actuated valve was only 12 years old, it required frequent movement to provide adequate flow control.
Although numerous attempts had been made over the years to optimise the valve performance, it still required actuating every 10 minutes.
Also, the valve constantly oscillated under load conditions and required frequent servicing, which was proving inconvenient and costly, due to its relatively inaccessible location.
The Thames Water main contractor - Costain - consequently tasked the process valve manufacturer Erhard to come up with a suitable alternative.
Erhard chose to base the new valve design on a pneumatic, rather than electrical, actuator.
This offered a much more robust control solution, with minimal maintenance requirements.
The valve pneumatic actuator is a custom designed unit produced by Festo, which is coupled directly to the butterfly vane without gearing or spindles.
The system is controlled by a remote Siemens PLC, with local operator override facilities for routine inspection.
Pneumatic valve actuators provide interesting cost and performance benefits for process valve actuation.
Pneumatic cylinders are inherently compact actuators with high force capacities and overload capabilities.
Using compressed air as the drive medium provides a safe and reliable solution that copes with fluctuations in actuation forces, temperature and humidity and delivers an operating life of more than 2 million cycles - which is up to 10 times more than a typical electrically operated valve.
Given the importance of the Ashford Common contribution to London's water supplies, it was essential that the valve replacement was handled as quickly and efficiently as possible.
Festo service partner Aspects Engineering successfully carried out all system installation tasks.
The entire procedure was rehearsed repeatedly prior to implementation, to ensure that no last-minute problems would be encountered by the engineers while working in the confined space of the shaft.
It says much for the professionalism of all parties that the entire task was completed in just 16 hours - some 8 hours less than the allocated time.
The valve was replaced on December 7, 2005, which went completely unnoticed by the company's customers, though it did win an accolade from Phil Stride, Thames Water Director of Operational Control, who called it "an exemplary piece of work, well-planned and executed, which enabled Ashford Common to return to full production ahead of schedule".
According to Paul Davies, Thames Water Project Manager, "We are exceptionally pleased with the performance of this valve.
It is much more responsive to control signals and oscillates significantly less than its electrically-actuated predecessor.
As a result, we expect less premature valve wear.
It seems apparent that pneumatically-actuated valves offer numerous operational advantages over electrically-actuated valves in this environment.
I have also been very pleased with the technical support provided by Festo during this project and we are now considering pneumatic actuation in other areas". Request a free brochure from Festo ...