Guernsey Water has adopted various valve solutions recommended by Festo at one of the island's water treatment plants to improve the supply of drinking water to about 24,000 households and businesses.
Nearly 66,000 people rely on the company's daily output of about 12 million litres - a figure that rises significantly during the summer months when the island's population is boosted by tourists.
One of the membrane filters at Guernsey Water\'s treatment plant at St Saviours.
To maintain this level of supply from a water catchment area of just 43km2, Guernsey Water operates 16 reservoirs and water storage quarries with a total capacity of 4,425 million litres - about 10 months' supply - together with three water treatment plants and 409km of water mains.
The water treatment plants are located at St Saviours, Longue Hougue and Kings Mill.
The St Saviours and Longue Hougue plants use the latest membrane filters, while the Kings Mill plant, which is only used to meet summertime demand or as a back-up in the event of a failure at either of the other two plants, uses earlier-generation clarification and rapid gravity filtration treatment.
The St Saviours plant, which originally used chemical coagulation and rapid gravity filters, underwent a substantial upgrade in 2004, which led to the introduction of ultra-fine membrane filtration.
Membrane filter systems designed for water treatment plants provide a much more compact, higher-performance filtration solution than traditional systems using chemical clarification and sand bed filter combinations and are said to be more cost effective in use.
Most of these systems comprise a series of removable modules, each containing a set of fine-tube membranes that allow the passage of water, but that prevent any suspended particulates and biological contaminants from passing through.
The impurities are left clinging to the outsides of the hollow-fibre membranes and are removed by a series of regular purging, or scourging, routines.
The membrane filter system at St Saviours comprises four banks of filter modules, together with their associated valves and control unit.
It operates completely automatically, using compressed-air back pulses to clean the filters every 15 seconds.
When the system was first installed, it performed much as expected, ensuring a high flow rate of quality drinking water for distribution to Guernsey Water's customers and load-balancing service reservoirs, with minimal maintenance requirements.
However, after about 18 months of operation, the system's purging valves began to fail, resulting in higher maintenance overheads and unacceptable levels of system downtime.
The valve supplier recommended installing an air lubrication system, but this merely served to compound the problem.
Andrew Benstead, water production manager for Guernsey Water, said: 'During a visit to a trade show last year, I happened to mention our ongoing valve issues to an automation specialist, who suggested that I should contact Festo.
'By then, we were experiencing up to three faults a week - some of these were genuine, while others were being flagged up erroneously due to signalling problems,' he added.
After conducting an onsite survey, Festo ascertained that the principal cause of the purging valve problem was the choice of technology.
The existing valves were butterfly-type units, which, typically, have an operational life of between 500,000 to one million cycles.
Given that the membrane filters at the St Saviours plant are purged every 15 seconds and that each bank of filter modules is generally in use for 200 days a year, the valves could easily have failed about a year after installation, according to Festo.
The St Saviours plant was also experiencing a high incidence of solenoid valve failures, which Festo discovered was caused by water ingress, exacerbated by incorrect valve orientation and inadequate environmental protection.
Another problem was that valve wear had damaged some of the actuator drive shafts, leading to errors in their end-position signals, which culminated in false indication of operational status.
To overcome the principal problem of the premature failure of the air-purging valves, Festo recommended that they be replaced with more appropriate technology, in the form of actuator-driven pinch valves.
The type specified by Festo has a typical operational life of 10 million cycles - equivalent to more than eight years of use with the duty cycle employed at the St Saviours plant.
Festo also recommended using non-contact end-position sensors on all the pinch valves to eliminate the effect of drive shaft wear and the installation of a suitable cabinet to help keep the solenoid valves clean and dry.
Further refinements included removing the unnecessary air lubrication system and adding a number of Festo quarter-turn actuators and switch boxes, a 10in (25cm) butterfly valve for water flow control and an extra high-performance silencer to further reduce the sound of exhaust air.
Guernsey Water decided to trial the recommendations on one of the four membrane filter banks first, before proceeding with the other three if the results proved satisfactory.
Most of the hardware was installed by Guernsey Water's engineers, while Festo provided assistance with air connections, wiring (including connection to the site's PLC) and commissioning.
The work was completed in July 2008.
Benstead said: 'Aside from a minor signalling issue back in September, which Festo promptly resolved, everything has worked flawlessly since switch-on.
'We have experienced no faults whatsoever, which means that maintenance overheads at the St Saviours plant have reduced significantly.
'In fact, we were so impressed with the system's performance that, at the beginning of this year, we ordered replacement valve systems for the other three membrane filter banks and work is just about to start on installing these,' he added.
Not what you're looking for? Search the site.
Tel +44 1252 775000
-
Pneumatic drive units ideal for wastewater plants
Festo has launched a series of highly integrated pneumatic drive products that are ideal for wastewater treatment plants or systems used in the chemical industry -
London's water runs better on pneumatics
A 1600mm butterfly valve at the Thames Water Ashford Common water treatment plant is now controlled by a pneumatic actuator system designed and produced by Festo -
Festo jet valves provide 1ms switching time
Festo has launched a series of jet valves providing switching times of less than 1ms - an order of magnitude said to be faster than standard pneumatic solenoid valves. -
Festo actuators offer +/-10 micron repeatability
Festo has released a range of ultra-compact precision electric actuators that can be ordered from its online shop. -
Festo offers Codesys controller for CPX terminals
Festo has launched a Codesys embedded controller for use with its CPX series of multifunctional control terminals.
Browse by category
- Plant Instrumentation (6592)
- Process Control and Management (3043)
- Communications and HMI (2978)
- Process Plant and Equipment (7478)
- Processing Industry Events and Services (3630)
- News from specific industry sectors (2847)
- Environment, Pollution + Green Power (903)
- Flow Measurement (949)
- Water Industry News (1552)
- Water News and Legislation (144)
- Water Industry Events: IWEX (163)
- Hydrometry, Environment and Floods (164)
- Water Saving, Re-use and Recycling (23)
- Desalination (17)
- Potable water, test and treatment (277)
- Potable water metering and distribution (125)
- Pure water: UV and Membrane systems (122)
- Trade effluent monitoring + on-site treatment (133)
- Waste-water handling, monitors + treatment (250)
- Sludge Handling and treatment (101)