Product category:
Gas and Steam Flow Measurement
News Release from: Fluid Components International | Subject: Model GF90
Edited by the Processingtalk Editorial
Team on 27 July 2006
Self-cleaning mass flow meter reduces
maintenance
Innovative self-cleaning purge ports mean the Model GF90 Flow Meter maintains optimum flow measurement performance while dramatically reducing maintenance costs in rugged industry applications
With its innovative self-cleaning purge ports, the Model GF90 Flow Meter from Fluid Components International (FCI) maintains optimum flow measurement performance while dramatically reducing maintenance costs in rugged industry applications where dirt, grit and grime are present in the fluid The insertion style GF90 Mass Flow Meter self-cleaning purge ports minimise maintenance requirements and costs in dirty gas applications
This article was originally published on Processingtalk on 3 Jun 2008 at 8.00am (UK)
Related stories
Two-wire level monitoring and interface control
The rugged NuTec LS2000 Level Switch provides highly reliable level monitoring and interface control in demanding process industries, giving low maintenance, long-life and low cost-of-ownership
Thermal mass flowmeter for hazardous areas
The new ST50 flowmeter delivers exceptional performance, installation versatility and economy in air, compressed air or nitrogen and a variety of other processes gases, as well as plant HVAC systems
In many process or manufacturing plants, technician access to flow meters for inspection or maintenance can be problematic due to their location.
By connecting the GF90 purge ports to compressed air, inert gas or solvent purge lines, process contaminants can be removed regularly and without un-installing the flow sensor element from the pipe to ensure continuous high accuracy measurement and significantly reduce maintenance activity.
The versatile GF90 utilises a thermal mass gas flow sensing element designed with 316 stainless steel and nickel-braze construction.
Further reading
Space-saving Hydrogen flowmeter is approved
The new space-saving ST75V Hydrogen flowmeter with agency approvals for hazardous areas is ideal for oil/gas refineries, ammonia production, food plants, mining, and fuel cell skids
Best practices engineering guide provides help FOC
The 'Best Practices Engineering Guide', and Installation Recommendations for FCI single-point, thermal dispersion flowmeters addresses actual field conditions, and is available on the website
Flow and liquid level interface switch is SIL2
Built to comply with process industry precision requirements for flow, level and interface sensing in liquid, gas or foam, the innovative FLT93 Switch Series is now rated SIL2 compliant
It also can be specified with corrosion and abrasion-resistant alloys, including Hastelloy, Monel and tantalum, and with all-welded construction for service in the harshest environments.
It is available for service in broad range of fluid temperature applications, from -100 to 850F (-73 to 454C) and pressure applications to 1000 psig [69 bar].
With constant power technology, the GF90 Flow Meter features turndowns from 1000:1, with an accuracy of 1 percent of reading plus 0.5 percent of scale, with repeatability of +0.5 percent of reading or better.
Flow sensitivity is from 0.25 to 1600 SFPS [ft/sec at a standard temperature of 70F and pressure of 14.7 psia] or 0.08 to 487.7 NMPS [m/sec at a normal temperature of 21.1C and pressure of 1.013 bar absolute].
Combining a rugged, low maintenance design with exceptional features, the GF90 is ideal for use in chemical plants, electric power utilities, oil/gas processing, pollution monitoring, steel, and wastewater treatment.
Typical flow measurement applications include: fly ash, flare gases, blast furnace gases, smokey cyclone separator air flow, landfill gases, digester and bio-gases, stack pollution monitoring and dirty gas in filter production.
Developed for complex multi-gas or variable flow processes, the GF90 Flow Meter includes an advanced microprocessor-based programmable transmitter.
The transmitter can store up to three calibration groups.
Each group can be independently configured for a specific calibration range, fluid, switch point settings, etc, to provide accuracy in complicated gas processes.
The instrument is also inherently multi-variable, providing both flow and temperature measurements without any additional tap points.
The GF90 transmitter electronics are addressable via a built-in LCD display and keypad or through its RS-232C and RS-485 serial ports.
This allows the user to perform in-field programming to change zero, span, switch points and engineering units, or to perform instrumentation verification, troubleshooting and other critical functions.
The serial I/O ports support access to computers or ASCII terminals.
The GF90 transmitter features two independent, field programmable analogue signal outputs of 4-20 mA, 0-10 Vdc, 0-5 Vdc, and/or 1-5 Vdc, which can be assigned to any combination of flow and/or temperature.
It also offers dual alarm switch points with relay outputs.
The switch points are user, field programmable to alarm at high, low or windowed and can also be assigned to flow and/or temperature readings.
Dual 10A relay outputs are provided for contact closures to lamps, alarm and control systems.
A NEMA Type 4X (IP66) rated transmitter enclosure is standard, with configuration options for local or remote mount application.
Optional Class I and II, Division 1 and 2, Groups B, C, D, E, F and G [EEx d IIC] transmitter enclosures are also available with agency approvals for Factory Mutual Research, CSA and ATEX.
Fluid Components International is a global company committed to meeting the needs of its customers through innovative solutions to the most challenging requirements for sensing, measuring and controlling flow and level of air, gases and liquids.
• Fluid Components International: contact details and other news
• Email this article to a colleague
• Register for the free Processingtalk email newsletter
• Processingtalk Home Page