Product category:
Gas and Steam Flow Measurement
News Release from: Fluid Components International | Subject: ST75V
Edited by the Processingtalk Editorial
Team on 21 June 2007
Reliable metering for small line gas
mass flow
The ST75V air/gas flow meter provides a highly-accurate, reliable mass flow measurement solution for hydrogen, natural gas, and other gases in small line processes and for skid-mounted equipment
The new ST75V flowmeter from FCI delivers breakthrough performance in a space-saving design that simplifies installation and reduces costs, measuring hydrogen, natural gas, and all other gases in chemical processing, electric power, food/beverage, oil/gas refining, metals and manufacturing plants The ST75V combines highly reliable, no-moving parts thermal mass flow sensing technology with built-in precision Vortab flow conditioning to achieve 1% of reading, 0.5% full scale accuracy, in line sizes from 0.25 to 2.0 inches (6 to 51mm)
This article was originally published on Processingtalk on 1 Apr 2008 at 8.00am (UK)
Related stories
Space-saving Hydrogen flowmeter is approved
The new space-saving ST75V Hydrogen flowmeter with agency approvals for hazardous areas is ideal for oil/gas refineries, ammonia production, food plants, mining, and fuel cell skids
Two-wire level monitoring and interface control
The rugged NuTec LS2000 Level Switch provides highly reliable level monitoring and interface control in demanding process industries, giving low maintenance, long-life and low cost-of-ownership
It sets a new industry price-performance standard for mass flow measurement accuracy at an economical installed cost--with low maintenance and low lifecycle costs as well.
In many applications, either space limitations or other devices, such as valves or elbows, make it impossible to install a flowmeter with the required upstream/downstream straight-pipe run.
This results in swirl and flow profile disturbances that invalidate the flowmeter accuracy.
Further reading
Thermal mass flowmeter for hazardous areas
The new ST50 flowmeter delivers exceptional performance, installation versatility and economy in air, compressed air or nitrogen and a variety of other processes gases, as well as plant HVAC systems
Best practices engineering guide provides help FOC
The 'Best Practices Engineering Guide', and Installation Recommendations for FCI single-point, thermal dispersion flowmeters addresses actual field conditions, and is available on the website
Flow and liquid level interface switch is SIL2
Built to comply with process industry precision requirements for flow, level and interface sensing in liquid, gas or foam, the innovative FLT93 Switch Series is now rated SIL2 compliant
The ST75V solves this problem with built-in flow conditioning that eliminates media disturbances while reducing the needed pipe straight-run by up to 70%.
The ST75V integral Vortab flow conditioner features a unique, engineered array of tabs.
They provide rapid cross-stream mixing to remove swirl and velocity problems, creating a smooth, fully developed flow profile for accurate measurement.
There is also virtually no pressure loss with Vortab technology, which reduces plant energy costs by optimising throughput.
Blending high accuracy with extensive features, the ST75V measures process gas or air flows from 0.01 SCFM (0.01 NCMH) to 559 SCFM (950 NCMH).
Ideal for both low-flow and high-flow applications, the ST75V provides three unique outputs of the mass flow rate, totalised flow and media temperature.
The ST75V was developed to be the highest-accuracy, lowest cost, small-line thermal mass flow solution for processes that flow hazardous fuel gases such as hydrogen, natural gas, methane, as well as air, oxygen, nitrogen and all inert gases.
It is ideal for use in fuel and air feed lines to furnaces, burners, industrial ovens, heat treating systems, boilers, and power co-generation equipment found in the manufacturing and process industries.
The ST75V's sensor design is all-welded stainless steel with Hastelloy-C tips that provide extra protection against invasive conditions within the pipe.
This rugged design also features no orifices or moving parts to clog or foul, which eliminates unplanned shutdowns, reduces maintenance and extends sensor life.
The transmitter is enclosed in a rugged, all-metal, dust and water resistant, NEMA Type 4X (IP67) rated package which is FM and ATEX agency approved for installation in hazardous locations.
The ST75V is an ideal replacement for differential pressure, orifice plate, turbine and vortex technology meters in rugged or dirty plant environments.
In compressed air systems, where energy savings can be realized by increasing efficiency, the ST75V is sensitive enough at low flows to signal leakage.
Superior installed accuracy is assured with the FCI Calibration Laboratory, which calibrates the ST75V to actual gases, such as hydrogen, rather than the typical industry practice of setting to only an air equivalency.
The ST75V standard outputs are fully scaleable 4-20mA and 0-10V that are user assignable to flow rate and/or temperature and a 0-1kHz pulse output of total flow.
The instrument can be ordered for powering by 24Vdc or 115/230VAC, with or without a built-in LCD digital display, and in local or remote-mounted electronics configurations.
Fluid Components International is a global company committed to meeting the needs of its customers through innovative solutions to the most challenging requirements for sensing, measuring and controlling flow and level of air, gases and liquids.
• Fluid Components International: contact details and other news
• Email this article to a colleague
• Register for the free Processingtalk email newsletter
• Processingtalk Home Page