Accurate air flow measurement in large
ducts
The innovative Master-Touch "FAT" Flow Averaging Tubes provide accurate measurement of gas or air flows in large pipes and ducts, without the expense and complexity of traditional multipoint systems
Flotech Solutions announce the innovative new Master-Touch "FAT" Flow Averaging Tubes from Eldridge Products These Master-Touch FAT units provide accurate measurement of gas or air flows in large pipes and ducts, without the expense and complexity of traditional multipoint systems
This article was originally published on Processingtalk on 20 Nov 2007 at 8.00am (UK)
Related stories
Thermal mass flowmeters with Foundation fieldbus
Brooks Instrument announces Foundation fieldbus I/O communications options for its thermal mass flowmeters, mass flow controllers, and pressure controllers
Brooks thermal mass flowmeters now rated at IP66
The Brooks Instrument thermal mass flowmeters and controllers available in the UK from Flotech Solutions are now weatherproof and conform to the IP66 classification
These units offer a cost-effective solution for Heating, Ventilation, and Air Conditioning (HVAC) and Variable Air Volume (VAV) applications, introducing only a minimal obstruction to the flow in the duct.
The thermal technology used in the measurement sensor involves a solid state instrument using the principle of convective heat transfer to directly measure mass flow.
The Flotech Eldridge sensors consist of two resistance temperature detectors (RTDs).
Further reading
Eletta flow switches from Flotech Solutions
At MTEC this year, Flotech Solutions, of Stockport, announced that they have recently been appointed as the exclusive UK sales representatives for Eletta Flow AB of Sweden
Emerson names Flotech as exclusive UK distributor
Emerson Process Management has named Flotech Solutions as their exclusive distributor for the KDG Rotameter and Brooks VA flowmeter ranges throughout the UK, effective from September 1st 2007.
A forced null Wheatstone bridge preferentially heats one RTD; the other RTD acts as the temperature reference.
The process gas flow dissipates heat from the first RTD, causing an increase in the power required to maintain a balance between the RTDs.
This increase is directly related to the rate of gas flow past the sensor.
The Eldridge sensors are temperature compensated and insensitive to pressure changes.
No additional instrumentation or calculations are required.
The output signal is a true mass flow signal which can be directly interfaced with your data acquisition system.
The Master-Touch FAT probes utilise a flow averaging tube to give a stable flow signal in applications where the flow profile is less than ideal, such as downstream of a bend, valve, tee or obstruction.
The flow averaging tube is sized to fit across the pipe or duct, and has a number of large diameter (0.125'') inlet ports along the length of the upstream impact surface.
The impact pressure from the flow at each inlet port produces an axial flow up the FAT tube, averaged inside the tube.
This is directed across the single flow sensor, to measure the total, averaged sensor flow.
The gas flow then passes back into the main flow stream via the downstream gas return ports located near the flow sensing element.
Because of the inherent flow averaging across the profile with the Flotech FAT sensor, the Flow Averaging Tube technology significantly reduces the traditional requirements for straight, unobstructed upstream piping at the measurement point.
Depending upon the piping configuration, the traditionally required upstream straight run can be 10, 20, even 50 diameters.
By measuring the cumulative flow velocities within the probe across the whole duct, the Flow Averaging Tubes are far more tolerant of flow profile problems than other instrument technologies.
This allows the required straight run to be greatly reduced.
And, when coupled with Flow Straightening Plates, the upstream requirement can be reduced to as little as three diameters. Request a free brochure from Flotech Solutions ...