Fasttracka II sensor detects water contamination
Chelsea Technologies has announced that its Fasttracka II system has successfully detected a contamination event at a UK water pumping station.
The event was automatically detected using the Fasttracka II fast repetition rate (FRR) chlorophyll a fluorometer combined with a red, amber green (RAG) algorithm, which has been developed to provide continuous, real-time protection for water supplies at the pre-treatment stage.
A discharge of Triclosan at a concentration of 22.6ug l-1 was detected by one of a number of Fasttracka systems within an ongoing evaluation programme involving UK sites operated by Veolia Water, United Utilities and Scottish Water, plus one site in the US.
All Fasttracka II sensors within this trial are installed at the water intake of pumping stations, with natural flora providing the target material for FRR measurements.
The RAG algorithm provides a clear display of the water condition and alarms when a contamination event is detected.
Since each FRR sequence requires only 2.7ms, the system is said to provide very high temporal resolution (currently set at one acquisition per minute), while allowing for use of a low-maintenance, flow-through arrangement.
Using data from the evaluation programme, the RAG algorithm has now been developed to the point where it provides effective rejection of false positives, while maintaining high sensitivity to contamination events.
Dr Kevin Oxborough from CTG presented results from the evaluation programme to a special interest group from UK water companies, at a meeting hosted by Veolia Water (Hatfield).
The presentation included results from independent laboratory tests, which showed that the combination of Fasttracka II sensor and RAG algorithm is effective in the detection of a range of toxicants.
Other features of the system discussed included the self-cleaning design of the sample chamber, the ability to function at high turbidity levels, the high dynamic range and the real-time measurement of chlorophyll a concentration.
The potential for using FRR technology for algal bloom detection was also discussed.
Not what you're looking for? Search the site.
Browse by category
- Plant Instrumentation (6593)
- Process Control and Management (3043)
- Communications and HMI (2978)
- Process Plant and Equipment (7478)
- Processing Industry Events and Services (3629)
- News from specific industry sectors (2847)
- Environment, Pollution + Green Power (903)
- Flow Measurement (949)
- Water Industry News (1552)
- Water News and Legislation (144)
- Water Industry Events: IWEX (163)
- Hydrometry, Environment and Floods (164)
- Water Saving, Re-use and Recycling (23)
- Desalination (17)
- Potable water, test and treatment (277)
- Potable water metering and distribution (125)
- Pure water: UV and Membrane systems (122)
- Trade effluent monitoring + on-site treatment (133)
- Waste-water handling, monitors + treatment (250)
- Sludge Handling and treatment (101)