Radio HPLC software satisfies CFR Part 11
All LabLogic software implements the full requirements of the ruling in FDA 21 CFR Part 11 relevant to radio HPLC systems, as used by drug metabolism laboratories
Drug metabolism laboratories grappling with the implications of the FDA 21 CFR Part 11 for their radio HPLC systems can be confident that current versions of all LabLogic software implement the requirements of the ruling.
The enhancements the company has made, which were discussed at length with users before introduction, encompass the ADME laboratory information management system Debra; Laura, for data collection and analysis; Seescan (QWBA image analysis); Trace (genealogy method development); and Jane, for liquid scintillation counters.
All are classed as closed systems and the six controls defined by the FDA operate in accordance with CFR Part 11 in every case, as described in full on the website.
The key features can be as summarised as follows.
· Validation - unique instrument interface details validate raw data and ensure it came from the correct source.
· Security Controls - a combination of usernames and passwords ensures that only authorised individuals can use the system.
· Audit Trails - accurate and complete copies of records can be generated in both human-readable and electronic form.
· Electronic Signatures - each area that could require a signature is configurable, allowing a wide range of options for administrators without loss of compliance.
· Signature/Record Linking - when a user signs the details are recorded, and the signature cannot be transferred to another set of data.
· Identification Components - each user must have both a user name and a password, ensuring that at least two distinct identification components are employed.
Not what you're looking for? Search the site.
Tel (UK)
-
New release of radio chromatography data software
A completely new regression analysis module along with further improvements to HPLC system control, document management and summary table reporting feature in the latest release of LabLogic Laura 3.4 -
Gamma detector is ideal for radio-HPLC counting
The Gamma-RAM radio-HPLC detector from LabLogic Systems is ideally suited for working on a daily basis with soft and intermediate gamma emitters with energies up to about 1 MeV -
Schering goes live first with new ADME LIMS
Schering AG in Berlin is the first pharmaceutical company to go live with the 5.6 version of Debra, the LabLogic Systems drug metabolism LIMS -
MDS Pharma Services upgrades drug metabolism LIMS
The Montreal facility of drug discovery and development specialist MDS Pharma Services has upgraded to release 5.5.8 of Debra, the leading ADME LIMS from Lablogic Systems. -
Radio HPLC detector is GLP-compliant
A flowcell identification system to meet GLP requirements is one of the features of the new Model 4 Beta-RAM on-line radio HPLC flow-through detector
Categories
- Plant Instrumentation (5,478)
- Process Control and Management (2,525)
- Communications and HMI (2,535)
- Process Plant and Equipment (6,164)
- Processing Industry Events and Services (3,198)
- News from specific industry sectors (2,263)
- ENVIRO-Talk - Environment + Pollution (550)
- FLOWtalk - Flow Measurement (753)
- WATER-Talk - Water Industry News (1,211)