Gamma detector is ideal for radio-HPLC
counting
The Gamma-RAM radio-HPLC detector from LabLogic Systems is ideally suited for working on a daily basis with soft and intermediate gamma emitters with energies up to about 1 MeV
The Gamma-RAM radio-HPLC detector from LabLogic Systems is ideally suited for working on a daily basis with soft gamma emitters such as Iodine-125 and Tc-99, and with intermediate gammas with energies up to about 1 MeV Although Beta counters are capable of such tasks on an occasional basis, their counting efficiencies are low and sometimes unacceptable, and their poor resolution precludes analysis of two gamma emitters in the same sample
This article was originally published on Processingtalk on 20 Mar 2006 at 8.00am (UK)
Related stories
New release of radio chromatography data software
A completely new regression analysis module along with further improvements to HPLC system control, document management and summary table reporting feature in the latest release of LabLogic Laura 3.4
Schering goes live first with new ADME LIMS
Schering AG in Berlin is the first pharmaceutical company to go live with the 5.6 version of Debra, the LabLogic Systems drug metabolism LIMS
To overcome these shortcomings, the Gamma-RAM has a heavy lead shield and a well-type titanium-activated NaI crystal, which has greater stopping power for gammas, giving high counting efficiencies, even for more energetic isotopes, and superior resolution that makes dual isotope counting practical.
The detector employs a hermetically sealed crystal/photomultiplier assembly, and both variable and fixed volume counting cells are offered for use with HPLC eluates.
Suitable for low energy emitters only, the variable volume cell consists of a Teflon tubing coil wound around a mandrel.
The coil in turn is surrounded by a cylindrical tungsten sleeve that can be moved in or out with a micrometer, exposing more or less of the coil to the surrounding sodium iodide.
Effective volumes from about 15 microlitres to 200 microlitres are possible.
For unusually high activity levels or more energetic isotopes, fixed volume cells made of stainless steel chromatography tubing are recommended.
The U-shaped tubing is surrounded by a lead or tungsten plug except at the bottom, giving exposed volumes as small as 5 microlitres.
This type of cell is especially useful for preparative work where the activity levels might otherwise overwhelm more conventional coil cells. Request a free brochure from Lablogic Systems ...