Thinking of buying an AAS or ICP? Read this first!
Read this first! Here are 10 good reasons why you should consider buying a 757 VA Trace Analyser instead!
These are 10 good reasons why you should consider buying a 757 VA Trace Analyser instead.
The 757 offers lower limits of detection (LOD) than spectroscopic techniques, parts per trillion limits of detection are easily achievable (new directives on effluent monitoring and drinking water regulations now mean even lower LOD's are required).
Capital outlay is a fraction of AAS/AAGF/ICP/ICP-MS.
With an initial outlay of under UK PDS10K, even the smallest of laboratories can now monitor their own effluents.
Extremely low running cost, no expensive gases or lamps, just a single bottle of N2 and good quality water is all that is required.
No alterations to the infrastructure of your lab, ie no fume extraction required and no gas lines to be plumbed in.
Portable and space saving.
May be moved from lab to lab or site to site, and just occupying less than a metre of bench space.
Doesn't just analyse for heavy metals, can also do anions eg CN,NO3,S2-, I- plus certain organics.
Can speciate metals if required eg Cr3+ and Cr6+.
Calibrates each and every time via standard addition, eliminating many matrix effects seen in AAS or ICP.
Even normally difficult samples by spectroscopic techniques are easy eg salt solutions or plating baths.
Official methods available eg "Blue Book" "EPA" and DIN standards.
As one of the most versatile analytical techniques, Voltammetry serves a broad array of applications.
Metals, non-metals, anions, and organics can be determined in a wide range of sample matrices, including: foods/polymers beverages/plastics drugs/chemicals cosmetics/plating baths animal feeds/raw materials water/wastewater/pollution monitoring herbicides/pesticides.
If there is a very complex mixture of ions and molecules in the sample matrix eg seawater, Voltammetry can still monitor an ionic species down to parts per billion sensitivity.
A considerable increase in the sensitivity of polarographic and voltammetric methods can be obtained by enrichment of the substances to be determined prior to the polarographic or voltammetric determination itself, usually by electrolysis at a stationary working electrode.
The determination process is known as "inverse" because it generally takes place with the current flowing in the reverse direction to, that which was used, for the electrolytic enrichment.
In the simplest case, the enrichment electrolysis consists of the reduction of a cation to the free metal, which, for example, may be soluble in a stationary mercury electrode owing to amalgam formation.
If the enriched electrolysis, which may be likened to electrolytic extraction, is carried out under suitable conditions, the amalgam will contain a higher concentration of the element under investigation than was to be found in the original aqueous sample solution.
The concentration of the metal in the amalgam depends on the electrolysis conditions (such as time).
The "amalgam electrode" can carry out the actual voltammetric determination thus formed.
Suppose, for example, that we plot the current/voltage curve by normal DC Polarography in the anodic direction (i.e from the negative to a positive voltage); we will obtain a current peak whose height is a function of the concentration of the metal in the amalgam and hence, provided the electrolysis conditions were constant, of the concentration of the metal in the original aqueous sample solution.
Example :- Inverse Voltammetry is a highly sensitive analytical method enabling solutions on the ppb range and even below to be analysed with a high degree of efficiency using comparatively inexpensive apparatus.
After separation either as a mercury amalgam or on inert electrodes, the following elements can be determined: gallium, indium, thallium, lead, tin, antimony, bismuth, copper, silver, zinc, cadmium, mercury, manganese, iron, cobalt, nickel, etc Halides and a few other anions may be determined by using electrodes, which react chemically with them, while beryllium and aluminium can be determined after adsorptive enrichment.
Not what you're looking for? Search the site.
Tel +44 1280 824824
-
KF Coulometer determines water content in gases
Metrohm has developed a method to determine the moisture content of gases based on the ISO standard 10101: natural gas: determination of water by the Karl Fischer method. -
743 Rancimat for oxidative stability analysis
The Metrohm 743 Rancimat is a computer-controlled instrument for oxidative stability analysis of fats, oils and other rendered products, including biodiesel. -
Metrohm introduces the 797 VA Computrace
The Metrohm 797 VA Computrace can carry out trace metal analyses with the same or better sensitivity as an AAS or ICP instrument. -
Metrohm introduces the 859 Titrotherm
Metrohm's 859 Titrotherm thermometric titration system controls sulphate levels in wet process phosphoric acid production. -
Metrohm has analyser for food industry
The Metrohm Processlab is a fully customised, at-line automation analyser that uses proven hardware and software, including micro-sample loops, overflow pipettes, pumps, valves, stirrers and Dosinos.
Categories
- Plant Instrumentation (5,478)
- Process Control and Management (2,525)
- Communications and HMI (2,535)
- Process Plant and Equipment (6,164)
- Processing Industry Events and Services (3,198)
- News from specific industry sectors (2,263)
- ENVIRO-Talk - Environment + Pollution (550)
- FLOWtalk - Flow Measurement (753)
- WATER-Talk - Water Industry News (1,211)