Product category:
Liquid Analysis: Titration, HPLC, IC
News Release from: Metrohm UK | Subject: Automated titration system
Edited by the Processingtalk Editorial
Team on 30 October 2003
Ondeo Nalco use automated titration
system
With 3000 water samples analysed per month, Ondeo Nalco Pacific management decided to search for an automated solution and therefore contacted Metrohm: this reduced manual work required to a minimum
Founded in 1928 in Chicago, Illinois, Ondeo Nalco today is one of the world's leading companies in the sectors of water treatment, waste water purification and process optimisation Ondeo Nalco manufactures speciality chemicals and offers innovative technology programmes that help to improve the cost-efficiency of industrial plants as well as to minimise the consumption of resources and environmental pollution
This article was originally published on Processingtalk on 2 Jul 2008 at 8.00am (UK)
Related stories
Tighter process control in acid pickling baths
Online ion chromatography from Metrohm has enabled tighter process control of acid pickling baths, as the final cleaning stage prior to metal plating
The determination of acidity in soft drinks
Sparkling drinks are the main cause of increasing tooth erosion among teenagers: a study in the British Dental Journal found a strong link between fizzy drink consumption and tooth erosion
Apart from the chemical and pharmaceutical industries, it is above all, the food industry, the energy sector and the paper and textile industry that are Ondeo Nalco customers.
The Ondeo Nalco Pacific Technical Centre in Singapore has a laboratory for applied research and an analytical laboratory.
The latter provides services for customers and field engineers throughout the whole of Asian-Pacific region.
Further reading
The new Metrohm 856 conductivity module
The 856 Conductivity Module introduces the new 5-ring conductivity sensors which are far superior to the classical conductivity sensor
pH measurement of ethanol using the Aquatrode Plus
Investigations into the use of the Metrohm Aquatrode Plus electrodes for ethanol pH measurements according to ASTM D 6423 - the pH value is an important quality criterion for bioethanol
Determining organic additives in electroplating
ProcessLab-VA/CVS - the innovative process monitoring solution Voltammetry (VA) and Cyclic Voltammetric Stripping Analysis (CVS) are now available for routine analysis in the plant
It offers technical support for questions and problems in the following application areas; waste water, cooling water, boiler water, deionised water, ultra pure water and recycling.
Currently about 3000 water samples are analysed per month in the analytical laboratory, 90% of which are from Singapore.
These analyses were previously carried out manually and required a huge number of time consuming individual determinations.
In order to cope with the ever increasing number of samples, the Ondeo Nalco Pacific management decided to search for an automated solution and therefore contacted Metrohm.
The water analysis system in the automated titration system consists of a 736 GP Titrino, a 730 Sample Changer with swing out head, a 712 Conductivity meter, several Dosino (dispensers) as well as Metrodata Software.
32 x120ml water samples can be analysed in a single run.
A single sample aliquot is all that is required for determining four important water parameters throughout a wide concentration range: conductivity, pH value, carbonate hardness (alkalinity,p and m values).
The conductivity measurement must take place before the sample comes into contact with the glass electrode, as otherwise the electrolyte outflow from the pH electrode would falsify the measurement.
For this reason a special flow through conductivity cell is used; this is placed up stream from the titration cell.
For pH measurements and titration of the carbonate hardness a specially constructed double-junction pH glass electrode is used that guarantees short response times and stable measuring values even in ion-deficient water samples.
At the end of the determinations the analytical results are automatically exported to LIMS by TiNet software.
Water parameters determined Conductivity 10S.4000microS/cm pH value 5S.11 Carbonate hardness p value 10S.300ppm m value 10S.500ppm Chloride 10S.1000ppm.
The automated titration system from Metrohm completely fulfilled the expectations of the laboratory Manager, Mrs Sharyn Gaspari and her team.
The sample throughput has been considerable increased, resulting in improved efficiency.
During an 8 hour shift more than 70 water samples can be analysed.
The manual work required has been reduced to a minimum.
The personnel being freed from routine work, thus saving time for other activities.
Additional decisive advantages are the increased reliability and improved precision of the results.
This extremely positive experienced has led Ondeo Nalco Pacific to purchase a second Metrohm titration system in order to be able to keep on top of the expected increase in the number of samples. Request a free brochure from Metrohm UK ...
• Metrohm UK: contact details and other news
• Email this article to a colleague
• Register for the free Processingtalk email newsletter
• Processingtalk Home Page