Metering iodide in milk using IC +
inline dialysis
The Metrohm Inline Sample Preparation (MISP) for ion chromatography allows the determination of iodide in milk: the matrix of milk is removed by inline dialysis prior to sample injection
Iodine is an essential trace element It is found in dairy products, sea fish, sea salt or iodised salt
This article was originally published on Processingtalk on 2 Jul 2008 at 8.00am (UK)
Related stories
Tighter process control in acid pickling baths
Online ion chromatography from Metrohm has enabled tighter process control of acid pickling baths, as the final cleaning stage prior to metal plating
The determination of acidity in soft drinks
Sparkling drinks are the main cause of increasing tooth erosion among teenagers: a study in the British Dental Journal found a strong link between fizzy drink consumption and tooth erosion
Iodide levels in milk and milk powder can be easily analysed using anion chromatography with conductivity detection after chemical suppression.
Milk is of a quite complex constitution.
Especially the fat globules and casein micelles account for some unwanted matrix effects.
Time consuming external sample treatment procedures are no longer necessary if you use the superb Metrohm Inline Sample Preparation (MISP) for ion chromatography.
The matrix of milk is removed by inline dialysis prior to sample injection.
A compact ion chromatography system containing the 861 Compact IC and the 838 Advanced IC Dialysis Sample Processor MIC-7 Compact.
The 'MIC-7 Compact' is a Compact anion system with chemical suppression and dialysis The compact IC system with integrated dialysis.
For routine tasks and detection limits down to the ppb range, the combination of the 761 Compact IC with the 838 Advanced IC Dialysis Sample Processor is the optimal solution whenever contaminated samples have to be measured.
Dialysis is the method of choice whenever particles, oil droplets or coarse organic contaminants have to be kept away from the whole IC system.
The cellulose acetate dialysis membrane provides the necessary security without limiting the reproducibility and precision of the measurements.
As two valves are required for the dialysis, the 761 Compact IC is extended by one valve with the 812 Valve Unit.
The system is controlled by the IC Net software.
The separation column used is the Metrosep A Supp 5 - 150 separation column .
For further information please contact Metrohm UK. Request a free brochure from Metrohm UK ...