Product category:
Level and tank contents instrumentation
News Release from: Magnetrol International | Subject: EZ Modulevel
Edited by the Processingtalk Editorial
Team on 09 September 2004
FMEDA analysis on displacer level
transmitters
The smart EZ Modulevel of Magnetrol International is the first displacer transmitter with SIL (Safety Integrity Level) data according to IEC 61508, meeting the integrity requirements for SIL2
The smart EZ Modulevel of Magnetrol International is the first displacer transmitter with SIL (Safety Integrity Level) data according to IEC 61508 The FMEDA analysis shows that SIS designers can meet the integrity requirements with the EZ Modulevel up to SIL2
This article was originally published on Processingtalk on 22 May 2003 at 8.00am (UK)
Related stories
Loop powered radar for both interface and level
The Eclipse 707 is the first "radar type" level measurement that is able to measure both the upper liquid level and the liquid-liquid level interface over a 2-wire loop powered connection
No extra cost for SIL 2/3 compliant level switch
The Echotel 915P/W from Magnetrol International is a 2-wire level switch that can detect the high or low level of almost any liquid without calibration: a SIL 2/SIL 3 compliant device at no extra cost
Architectural requirements can be met to SIL1 (non-redundant) or SIL2 (redundant).
The smart EZ Modulevel is a 1oo1 (one out of one) level transmitter.
The PFDavg (average Probability of Failure on Demand) for a one year proof test interval is 8,94 x10-4.
Since the smart EZ Modulevel is equipped with a powerful microprocessor to allow a user friendly set up and diagnostic reporting, the device categorizes as a "Type B" device.
The FMEDA analysis was performed on all electronics and related hardware of the actual series - meaning that the report is also valid for the thousands of units installed around the world.
The report is available free of charge from Magnetrol.
The smart EZ Modulevel was first introduced in 1996 and services on process vessels up to 355 bar/ 315C for monitoring continuous level or interface measurement or as density controller.
Different from a traditional torque tube design, the EZ Modulevel uses a measuring spring.
The spring reduces the friction of moving parts (only one linear motion) and acts as natural damping.
The result is a more reliable and stable output even when the liquid surface is turbulent.
The "measuring spring" type units use an LVDT (Linear Variable Differential Transformer) with much higher resolution (accuracy/linearity) versus the torque tube design using typically an RVDT (Rotatable Variable Differential Transformer).
The EZ Modulevel has gained immense popularity worldwide on offshore platforms, petrochemical sites and power stations. Request a free brochure from Magnetrol International ...
• Magnetrol International: contact details and other news