Product category:
Telemetry, data acquisition + loggers
News Release from: Moore Industries International | Subject: NCS life test
Edited by the Processingtalk Editorial
Team on 04 March 2008
Data Acquisition System long-life
endurance test
An NCS Data Acquisition System has been running since February 2005 in an environmental chamber, at up to 221F, as a long life endurance test: biggest problem - the labels have turned brown
Moore Industries has been continuously running its NET Concentrator System (NCS) data acquisition system at temperatures hovering around the boiling point of water for more than three years in an environmental chamber "The only problem we've found so far is the labels are turning brown from the continuous, intense heat," reports Fred Adt, Director of Quality Assurance at Moore Industries: "But we've taken care of that problem by using more heat-resistant labels in new products"
This article was originally published on Processingtalk on 24 Jun 2003 at 8.00am (UK)
Related stories
HART loop interface module
Moore Industries new HIM smart HART Loop Interface and Monitor module unlocks the full potential of new and in-place "legacy" Smart HART transmitters, with no additional process penetrations or wiring
New Ethernet process control and distributed I/O
This Ethernet process control and distributed I/O network is designed specifically for demanding industrial applications, based on 35 years experience in precision transmitter technology
The NCS is equipped with several modules, including an EIM (Ethernet Interface Module), CPM (Concentrator Power Module), AIM (Analog Input Module), TIM (Temperature Input Module), DIM (Discrete Input Module), and ROM (Relay Output Module), all of which have also been in the environmental chamber for the three years.
Except for their labels turning brown, no problems have occurred.
Fred Adt explains that conventional testing and life-test procedures are not enough when products are intended for use in severe operating conditions, such as in the Middle East.
Further reading
OPC approves Moore Industries NET Concentrator
Moore Industries process control and distributed I/O network, the NET Concentrator System, has obtained OPC Foundation approval for the system OPC server, confirming connectivity and interoperability
PC-programmable Modbus temperature transmitter
Moore Industries new TMZ PC-programmable Modbus temperature and signal transmitter delivers high input resolution and exceptional digital measurement accuracy
NCS Network is now available with Modbus RS485
The Moore Industries NCS Process Control and Distributed I/O Network is now available with Modbus RTU (RS-485) communication capabilities for use over long distances and on twisted pairs, Ethernet etc
The NCS is intended for use as a remote control and data acquisition system in unheated and non-air conditioned enclosures, so it has to endure wide temperature extremes.
"The MTBF (Mean Time Between Failures) for the NCS, determined in accordance to the Bell Core reliability model, exceeds 300,000 hours at 25C," explains Adt.
But this model isn't good enough for Moore Industries.
Adt wants to find out how long the NCS will last under severe ambient conditions.
So Adt is using the Highly Accelerated Life Test (HALT) concept and uses the accumulated on-time to demonstrate MTBF at increased environmental stress from elevated temperatures.
Running at 90C provides a factor of 6.5; that is, every hour running at 194F (90C) is equal to running 6.5 hours at normal ambient temperatures.
Fortunately, meeting the test specs was not difficult.
Moore Industries products are designed for operation at ambient temperatures of -40C to +85C, so the test is just barely above its maximum design temperature.
"HALT lets us demonstrate performance of the NCS outside its specified environmental operational envelope," explains Adt: "The idea is that any failures induced that way might be consequently eliminated by design, thus creating a product with more margin to failure.
Therefore, we have been running a continuous HALT on the NCS since February 2005, at temperatures from 90 to 105C (194 to 221F), with open air applications in the Middle East in mind".
So far, it hasn't failed.
The NCS reached a HALT-demonstrated MTBF of 171,000 hours in February 2008, and remains in continuous test.
The HALT accumulates about 57,000 hours per year, so the test has just over two years to go before reaching 300,000 hours.
"We intend to reach 300,000 hours, and maybe beyond," notes Adt: "We knew the NCS could take it, but we were starting to worry about the environmental chamber.
This test proves that both the NCS and the environmental chamber are very tough products".
The specs for the NCS HALT are:.
Ambient Temperature: 90C (194F).
Test Commenced: February 8, 2005.
Models Installed: EIM, CPM, AIM, TIM, DIM, ROM.
Operation Mode: Temperature inputs are monitored via the EIM Ethernet communications port, and data is logged on a daily basis.
MTBF status: 1100 days times 24 hours/day = 26,400 hours.
According to the Arrhenius equation, the acceleration factor for 90C is 6.5.
This means a demonstrated MTBF of 171,600 hours has accumulated as of February 13, 2008.