Total radiological monitoring systems
BNFL and AEA have installed cost effective Omniflex radiological monitoring systems to collect data from their Harwell or Labimpex monitors for processing by plant SCADA systems
These systems enable data from their Harwell or Labimpex Alpha, Beta and Gamma monitors located anywhere within buildings or around larger site areas to be monitored by plant SCADA systems as well as providing real-time alarm management and building evacuation logic systems Omniflex can provide the ?Total Solution?
This article was originally published on Processingtalk on 29 Jul 2008 at 8.00am (UK)
Related stories
Distributed alarm and event management system
The Maxilarm Alarm and Event Management System offers features such as sub-millisecond time stamping at source, integrated analogue logging and remote alarm fascias all to meet EEMUA 191 guidelines
Alarm Windows improve safety and reaction times
It is now an accepted fact that traditional window alarm fascias provide the fastest means of alarm notification to operators when facing avalanche conditions
By using our well-proven Maxiflex distributed I/O system we can monitor the high speed RS422 pulsed signals and alarms from the Harwell 3230, 3280 range of Alpha Beta Monitors.
We can monitor the Harwell AB96 or G64 Alpha/Beta and Gamma monitors and the Labimpex CMS2000 Alpha, Beta and Gamma monitors via RS232/485 communications enabling multiple monitors to be linked on a single network.
The Maxiflex I/O system also provides interfacing to all SCADA systems via Modbus, Ethernet, Conet (any grade of 2-core cable up to 10kms without repeaters) and radio.
For more information on the solutions we can provide please contact us.
Alpha, Beta and Gamma monitors located anywhere within buildings or around larger site areas to be monitored by plant SCADA systems as well as providing real-time alarm management and building evacuation logic systems.
Omniflex can provide the "Total Solution".
By using our well-proven Maxiflex distributed I/O system we can monitor the high speed RS422 pulsed signals and alarms from the Harwell 3230, 3280 range of Alpha Beta Monitors.
We can monitor the Harwell AB96 or G64 Alpha/Beta and Gamma monitors and the Labimpex CMS2000 Alpha, Beta and Gamma monitors via RS232/485 communications enabling multiple monitors to be linked on a single network.
The Maxiflex I/O system also provides interfacing to all SCADA systems via Modbus, Ethernet, Conet (any grade of 2-core cable up to 10kms without repeaters) and radio.