'Omniterm' solves all your Loop problems

Request your FREE weekly copy of the Processingtalk email newsletter. News about Signal conditioners, isolators, modems and more every issue. Click here for details.

Instrumentation loop problems are frustrating at the best of times and downright time consuming affairs for plant maintenance staff to deal with: most problems relate to isolation and ground faults

Instrumentation loop problems are frustrating at the best of times and downright time consuming affairs for plant maintenance staff to deal with Most problems relate to isolation and ground faults, some of which present themselves intermittently or are hidden so deep in the plant wiring that tracing them becomes a full time job

The Omniflex Omniterm range of DIN rail mount loop isolators use advanced electronic techniques to address the common problems associated with instrumentation loops using several specialised new products.

The Omniterm LPI and LPX are current repeaters specifically designed to isolate instrument current loops from circulating ground currents that can cause system inaccuracies, or at worst instrument failure.

The current applied to the input is repeated on the isolated output, and the load on the output is reflected back to the input.

No separate power source is required.

These second generation products utilise advanced electronic techniques to achieve high accuracy with minimum loops losses and zero field calibration.

The LPI is optimised for lowest volt drop over 4-20mA, while the LPX is optimised for use with an extended current range from 0-50mA and load impedances down to zero ohms.

The Omniterm LPR current loop repeater and LPS current loop splitter products are specifically designed to create additional current loop signals from an existing current loop signal with minimal effect on the impedance of the existing loop.

The LPR has a single isolated output while the LPS has two isolated outputs.

These 24Vdc powered modules accept a 0-20mA or 4-20mA input and create 0-20mA or 4-20mA outputs.

The output current loops repeat the input signal and are isolated from the input signal and 24Vdc power supply.

Impedance changes on the output loops have no effect on the input loop.

The module input is fully differential allowing the input to be connected anywhere in the input loop.