Product category:
Shutdown, SIS and safety systems
News Release from: Pilz Automation Technology | Subject: Pilz PSEN
Edited by the Processingtalk Editorial
Team on 28 July 2006
Better ways to connect safety devices in
series
The Pilz PSEN multiple-sensor interfaces can connect to multiple emergency stop switches or other safety devices, and identify which safety device that has been actuated after a trip
Only the simplest of machines and processes have less than a handful of safety input devices, such as emergency stop switches; more often there will be multiple emergency stop switches, and there could well be other safety devices such as guard switches, safety mats, light curtains and laser area scanners Traditionally designers may have created safety circuits in which all of the emergency stop switches were connected in series and wired back to a single safety relay on the control panel
This article was originally published on Processingtalk on 2 Aug 2005 at 8.00am (UK)
Related stories
Light curtain for safety in whisky bottling plant
Chivas Brothers is renowned around the world for its exceptionally smooth Chivas Regal 12 and 18 Scotch whiskies, and now they depend on Pilz safety light curtains for smooth packaging operations
(Another) life-saver celebrates its 60th birthday
The National Health Service is to be congratulated on its 60th birthday, but there is another life-saving organisation that is also celebrating its 60th birthday this year: Pilz!
Similarly the other safety devices may have been connected in series with a single safety relay - or even connected in series with the emergency stop switches.
While such arrangements are likely to meet the basic safety requirements, they have their drawbacks.
For example, if an emergency stop switch is pressed or one of the guards is opened, there is no simple way to tell which device has been operated - unless auxiliary contacts have been individually wired back to a PLC or other controller to monitor the inputs.
Further reading
Pilz unveils extensive range of operator terminals
Pilz Automation Technology is launching a number of new human-machine interfaces, ranging from a compact diagnostic unit for safety-related control systems to larger units compatible with leading PLCs
IP67 digital input module for use with SafetyBUS p
Pilz Automation Technology is launching a new IP67 digital input module for use with SafetyBUS p, the safe, open industrial fieldbus system
Wireless modules enhance controller versatility
Pilz Automation Technology is launching new robust wireless links for use with its PSSuniversal modular controller for safety and standard automation applications in industrial environments
And without any diagnostic data, the process is likely to take longer to restart.
Wiring auxiliary contacts on a complex process or machine can add significantly to the cost in terms of the wiring time and the requirement to purchase extra I/O for the PLC.
However, Pilz has products available that can help to reduce the wiring and I/O requirement while still delivering diagnostic data and maintaining high levels of safety.
The Pilz PSEN ix1 multiple-sensor interface may be connected to four emergency stop switches or other safety devices, and a maximum of 12 PSEN ix1 interfaces can be cascaded to enable up to 48 inputs to be connected to a single safety relay in safety circuits conforming to the requirements of BS EN 954-1 Category 3.
LEDs on the front of the interface unit give a clear indication of the safety device that has been actuated.
Two versions of the PSEN interface are available, the PSEN ix1 for use with Pilz PSEN 1 series switches or other devices having two normally-open contacts, and the PSEN i1 for use with Pilz PSEN 2 series switches or other devices having one normally-closed and one normally-open contact.
This gives users a broad choice of input device and also helps end users that wish to upgrade existing safety circuits in order to benefit from improved diagnostics - and reduced downtime.
While the PSEN ix1 interface may be connected to a conventional Pilz X-range safety relay, the similar PSEN i1 interface can be used with a Pilz PNOZelog safety relay, a Pilz PNOZmulti modular safety controller or a Pilz PSS programmable safety system with or without a SafetyBUS p safety fieldbus.
If either the PNOZmulti or the PSS is used, the transistor indication outputs from the interface unit can be used to convey diagnostic data to the controller, which results in even faster recovery from a stoppage.
The PSEN interface units certainly have their advantages for BS EN 954-1 Category 2 and Category 3 applications, and Pilz has an alternative for Category 4 applications.
The Pilz PSENcode range of coded non-contact safety switches includes a uniquely coded version featuring matched switches and actuators that only work in combination with each other.
Virtually impossible to defeat, the switches provide an exceptional level of integrity.
Whereas a Category 4 application would normally require two mechanical switches per guard (to ensure mechanical redundancy), with each connected to a separate channel on a safety relay (for electrical redundancy), a single PSENcode switch can be used on each guard - and because the switches are intelligent and can remember their operating state, ten or more of these switches can be connected in series to a single safety relay.
This leads to considerable savings on hardware costs, as well as substantially simplified wiring.
Indeed, the switches can be connected to a Pilz PNOZ X-range or PNOZelog safety relay, a PNOZmulti modular safety controller, a PSS system or a SafetyBUS p network.
In addition, the PSENcode switches have a signal output that can be connected to a PLC, process controller or display so that an operator can immediately identify which guard has been opened.
Each switch also has high-brightness LED indication for local fault diagnosis.
Whether customers chose to use PSENcode switches on Category 4 applications or multiple-sensor interface units for Category 2 and 3 applications, they will enjoy high plant availability at an economical price.
Please contact Pilz to request more information about the PSEN i1 interface, PSEN ix1 interface and PSENcode sensors, or visit the website.