Product category:
Hazardous area interfaces, Enclosures
News Release from: R Stahl | Subject: ATEX
Edited by the Processingtalk Editorial
Team on 19 May 2003
30 June 2003 - ATEX goes live
After seven years, the transition period is almost over: on 30 June 2003, equipment suppliers will no longer be able use 'old approach' EC directives to operate in the European Union
From that date Directive 94/9/EC - the ATEX Directive - comes into force A harmonisation directive, the provisions included in 94/9/EC replace the existing divergent national and European legislation that covers the same subject - equipment and protective systems intended for use in potentially explosive atmospheres
This article was originally published on Processingtalk on 27 Apr 2005 at 8.00am (UK)
Related stories
New intrinsically safe isolator has IS in and out
A new intrinsically safe isolating repeater from R Stahl Schaltgeraete provides Ex-safe electrical isolation between two earthed circuits, and is approved for use in ATEX zones 1 and 21
Rugged laptops approved for ATEX zone 2
A new hazardous area laptop developed between Stahl and Panasonic is launched internationally this month, providing a range of robust, portable PC-based HMI systems
So after 30 June, "products may be placed on the market in EU territory, freely moved and operated as designed and intended in the expected environment, only if they comply with 94/9/EC".
The really important part of the new directive is that, for the first time, essential health and safety requirements are laid down for non-electrical equipment intended for use in potentially explosive atmospheres.
These requirements also cover equipment intended for use in environments which are potentially explosive due to dust hazards and protective systems, and devices intended for use outside explosive atmospheres which are required for or contribute to the safe functioning of equipment or protective systems with respect to risks of explosion.
Further reading
Stahl launch new generation IS isolator series
Paving a new direction in safety isolation, R Stahl has launched the IS isolator series, an innovative and future-leading series of modules for intrinsically safe circuits
Intrinsic safety engineering comes to fieldbus
Over the past 30 years, intrinsically safe (IS) explosion protection has developed into a mature and widely accepted technology: with fieldbus, intrinsic safety engineering must take a new direction
New generation of explosion-protected connectors
A new generation of explosion-protected plugs and sockets is now available for use in Zones 1, 2 and 22: the SolConeX series builds on the well-known and highly successful CES series
While the EC Blue Guide offers help in implementing this and other new directives, more detail is available on the EU Europa web site (www.europa.eu.int).
Of note for equipment suppliers are the thoughts of the ATEX standing committee, which met on 6 and 7 February to iron out some outstanding issues before the legislation goes live.
One of particular concern is the issue of quality assurance issue associated with document retention.
According to Annex IV, paragraph five of the ATEX Directive, the manufacturer - or where relevant the authorised representative or importer - shall, for a period ending at least ten years after the last piece of equipment was manufactured, be able to make available to the national authorities: the documentation of the quality system; information about updating of the quality system; and audit reports and certificates of the notified body.
Larger organisations have a certified quality management system according to the ISO 9000 standards.
For these manufacturers it is difficult to keep all quality documents and all changes to the quality system for such a long period.
So in the opinion of the standing committee, the requirements of this particular part of the legislation are fulfilled if manufacturer keeps at the disposal of the national authorities at least the actual quality management system documents plus the following documents which have to be kept for a period ending at least ten years after the last piece of equipment was manufactured.
Audit reports and certificates of the ISO 9000 certifier: this will be one or two audit reports per year that include the actual state at that moment of the quality system with changes.
Audit reports and notifications of the notified body that issued the production quality assurance notification.
The standing committee then went on to consider a number of specific equipment issues.
For example, it was felt that spray booths as an integral whole do not fall under the scope of the ATEX Directive and as such cannot be labelled with special markings for explosion protection.
It was also felt that plastic containers and tanks, as a general rule, did not fall under the scope of the Directive.
However, the committee considered that they might fall within the definition of a "component" as defined in Article 1 of the Directive.
The committee also considered the case of whether or not a pump/electric motor combination intended for use in potentially explosive atmospheres should be classified as electrical equipment within the meaning of Article 8.
It concluded that a distinction had to be made between two different circumstances.
For example, for the purposes of the Directive, a pump and electric motor constitute a "safety-related" device - they cannot be considered separately for the purposes of assessing explosion risks.
In this case, the unit as a whole is to be considered an item of electrical equipment.
A split tube motor pump falls into this category.
On the other hand, the pump and electric motor may form part of the same functional unit, but they do not constitute a "safety-related" unit for the purposes of explosion protection - no new explosion risks arise as a result of their being combined.
They do not therefore constitute an item of equipment which, as an integral whole, falls within the scope of Directive 94/9/EC, but rather a combination of "individual items of equipment" in terms of explosion protection.
In this case, therefore, pump and electrical motor must be considered separately in terms of the application of this Directive.
For more on these and other issues, contact R Stahl or visit the company website.
And remember that, after 30 June, no excuses will be accepted and no extensions granted to the transition period.
• R Stahl: contact details and other news
• Email this article to a colleague
• Register for the free Processingtalk email newsletter
• Processingtalk Home Page