Product category:
Hazardous area interfaces, Enclosures
News Release from: R. Stahl | Subject: IS pac 9164
Edited by the Processingtalk Editorial
Team on 27 April 2005
New intrinsically safe isolator has IS
in and out
A new intrinsically safe isolating repeater from R Stahl Schaltgeraete provides Ex-safe electrical isolation between two earthed circuits, and is approved for use in ATEX zones 1 and 21
A new intrinsically safe isolating repeater from R Stahl Schaltgeraete provides Ex-safe electrical isolation between two earthed circuits, for example between an intrinsically safe transducer and a standard 4-20 mA I/O module The module is approved for use in ATEX zones 1 and 21
This article was originally published on Processingtalk on 8 Oct 2008 at 8.00am (UK)
Related stories
R Stahl releases explosion-proof enclosures
R Stahl has introduced the GUbox (type 8265) range of explosion-proof enclosures approved for use in zones 1 and 2 as well as class 1 and division 1 throughout the world.
Stahl unveils helideck lighting range
Stahl has launched a helideck perimeter lighting range in line with CAP437 and ICAO regulations, which require helicopter landing areas to install new signalling equipment by January 2009.
The IS pac 9164 provides galvanic isolation to 4-wire analogue sensors, also supporting HART communications.
The repeater outputs an improved, intrinsically safe 2-wire output signal to a 4-20 mA module, such as the R Stahl Remote I/O System IS1.
This compact module requires no power supply because the required power is tapped from the 4-20 mA signal.
The IS Pac 9164 can be installed in ATEX Zone 1 and zone 21.
Two variants of the device are available, providing galvanic isolation between intrinsically safe areas, or from Ex e inputs resulting in an intrinsically safe output.
Earthed input circuits cannot be interconnected in hazardous areas because the signals could mutually influence each other in the event of a fault.
Electrical isolation with the mA-isolating repeater solves this problem and, at the same time, enhances the quality of the measured signals.
The Ex e input version of the device connects an Ex e measurement transducer to an intrinsically safe circuit, integrating Ex e devices into the Stahl intrinsically safe IS concept.
The mA-isolating repeater 9164 of R Stahl Schaltgeraete with e II 2 G (1) GD EEx ia IIC T4 and e II 2 G (1) GD EEx e mb [ia] IIC T4 approval.
It is suitable for installation in Zones 1, 21 and for connection of intrinsically safe circuits in Zones 0 and 1, and in Zones 20 and 21 dust Ex applications.
• R. Stahl: contact details and other news
• Email this article to a colleague
• Register for the free Processingtalk email newsletter
• Processingtalk Home Page