Product category:
Food Processing News
News Release from: Servomex | Subject: 574 portable gas analyser
Edited by the Processingtalk Editorial
Team on 27 January 2005
Gas analyser ensures freshness of coffee
pods
A revolution in coffee is spreading around the world, thanks to the Senseo brewing system developed jointly by coffee company Douwe Egberts and electrical appliance manufacturer Philips
A revolution in coffee is spreading around the world, thanks to the Senseo brewing system developed jointly by coffee company Douwe Egberts and electrical appliance manufacturer Philips One of the keys to its success is that within 1 minute it brews 1 or 2 cups coffee that tastes as if it is made with freshly ground real coffee, but without any mess or hassle
This article was originally published on Processingtalk on 3 Jul 2008 at 8.00am (UK)
Related stories
Measurement of nitrogen in argon and helium
Exceptional precision, proven reliability and impressive connectivity makes the Kontrol Analytik k2001 on-line analyser the best choice for the measurement of trace nitrogen in argon or helium
Oxygen analyser in catalyst production SIS loop
Sud-Chemie AG is one of the world's largest manufacturers of catalysts for the chemical and petro-chemical industries: Servomex process oxygen analysers play a crucial role in the plant safety
To ensure the unique coffee pods - which look similar to round tea bags - stay fresh in their outer packaging, Douwe Egberts is using a Servomex 574 portable gas analyser for each packaging line.
Roasted and ground coffee quickly loses its freshness if exposed to oxygen, so Douwe Egberts packages the coffee pods in sealed foil bags using nitrogen.
To ensure this vital process is being performed correctly sample packs are tested every hour.
Further reading
Petrochemical gas analysis for CEM and safety
A major Middle Eastern ethylene production (EO/EG) facility is using Servomex gas analysers for CEM (continuous emissions monitoring) and safety applications
Six combustion gas analysers help BP Chemicals
Servomex oxygen and combustibles analysers supplied for a refurbishment project at the BP Chemicals acetic acid production plant in Hull have contributed to a significantly reduced fuel consumption
MCERTS approval for N2O measurements
MCERTS approval makes Servomex infra-red gas analysers attractive to companies seeking to reduce Nitrous Oxide emissions and claim credits under the Kyoto protocol
There are packaging lines for the different blends of coffee and each has its own Servomex 574 portable oxygen analyser.
To perform a test the operator pierces the sample pack with a probe that consists of a hypodermic needle, the tip of which is surrounded by a foam pad to prevent the ingress of gases from the working environment.
A small volume of gas is then extracted by the analyser internal pump (an inline filter ensures only gases are drawn into the measurement cell), and the result is shown on the display in a matter of seconds.
Douwe Egberts already had experience of the paramagnetic technology used by Servomex in its oxygen analysers, having employed Servomex instruments in other packaging plants, so it had no hesitation in ordering four units for the first four packaging lines, then more as other lines were brought on stream to cope with soaring demand.
Paramagnetic sensing technology is the only feasible option for analysing oxygen in roasted coffee applications.
The reason for this is that roasting coffee produces a small amount of carbon monoxide that is absorbed by the coffee.
This slowly out-gasses and can lead to false negative readings on oxygen analysers that use high-temperature catalysts such as zirconia: if the gas sample is heated to 700 degrees C, the combustible carbon monoxide reacts with any oxygen present to form carbon dioxide.
Because the oxygen is consumed in this way, catalyst-based oxygen analysers tend to give a low or zero reading.
The Servomex 574 paramagnetic oxygen analyser, however, operates at ambient temperatures, so there is no opportunity for oxygen to combine with carbon monoxide.
Readings are therefore utterly reliable.
Furthermore, the non-depleting paramagnetic technology in the sensing cell enables operators to be certain that the analyser will always function correctly; in contrast, other sensing technologies can degrade, giving no indication that the readings are misleading.
Douwe Egberts has purchased one Servomex 574 for each packaging line, despite the fact that the instruments are portable.
Nevertheless, the small size and portability are beneficial because of the limited space available in the area around the packaging line and the ease with which the instruments can be carried back to a quality assurance (QA) laboratory for recalibration if required - though the Servomex 574 can be readily recalibrated in the production environment using nitrogen and/or air to maintain its accuracy of 0.2% oxygen with a repeatability of +/-0.1% oxygen.
In a QA application where several packs have to be tested in a short period, ease of use and speed of response are extremely important.
The Servomex 574 scores highly in both respects, plus it has an analogue output that can automatically feed data to a QA system for storage and analysis if required.
For more information about the 574 portable analyser and to discuss particular applications relating to coffee or other foodstuffs, please contact Servomex.
• Servomex: contact details and other news
• Email this article to a colleague
• Register for the free Processingtalk email newsletter
• Processingtalk Home Page